Precautions to take for wiring from the board
œDiscrete wire soldering
Follow the procedure below as you make wiring.
Specifications of this product are such that you mount a thin-wire coaxial connector on the board and then wire it with thin-wire coaxial cable. This product can also be used for crossed pin assignments by reversing the longitudinal direction of the connector as you attach it. In this case, draw out thin-wire coaxial cable from the opening in the wiring cover.
œDirection in which to mount a 0.4-mm pitch wiring connector

Click on this diagram to view it in a PDF.
About prlaceobe repment
(1) With the wiring board positioned on its back, remove the wiring cover and board. (Both are fixed in place with screws.)
(2) Draw out the degraded probe with tweezers and insert a new probe.
(The probes used in the CCDJ series are the double-acting type. They are connected to the wiring board by means of a probe contact and not connected by soldering. This means they can be easily removed.)
(3) Place the removed board and wiring cover back into position.
¡ CCDJ-030-pin number


Click on this diagram to view it in a PDF.
¡CCDJ-040-pin number


Click on this diagram to view it in a PDF.
|